Team report
Report: why B failed and C fixed it
Question: why did box B with the film window fail to shield the electroscope? With the comb 5 cm outside: bare electroscope 24°, A (sealed foil) 0°, B (film window) 9°, C (metal mesh window) 2°. A and B differ only in the window, so the window is the cause: film is a dielectric and does not block the field, while metal mesh works like a cage. Fix: replace the window with mesh (C), price with tax 7,920 soum, inside the 10,000 budget. Next step: seal the seams with two layers of tape. The numbers are examples.
— 8-B team